<?xml version="1.0" encoding="UTF-8"?><rss xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:atom="http://www.w3.org/2005/Atom" version="2.0"><channel><title><![CDATA[RSS Feed]]></title><description><![CDATA[RSS Feed]]></description><link>http://direct.ecency.com</link><image><url>http://direct.ecency.com/logo512.png</url><title>RSS Feed</title><link>http://direct.ecency.com</link></image><generator>RSS for Node</generator><lastBuildDate>Tue, 21 Apr 2026 10:52:57 GMT</lastBuildDate><atom:link href="http://direct.ecency.com/created/nfpa/rss.xml" rel="self" type="application/rss+xml"/><item><title><![CDATA[FIRE ALARM SYSTEMS 6-MAINTENANCE]]></title><description><![CDATA[BACKGROUND For reliable functioning of Fire Alarm System a periodic test program is crucial. It is clear that testing cannot prevent failures but rather help on identifying failures so reducing downtime]]></description><link>http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-6-maintenance</link><guid isPermaLink="true">http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-6-maintenance</guid><category><![CDATA[safety]]></category><dc:creator><![CDATA[angelparrales]]></dc:creator><pubDate>Wed, 16 May 2018 14:40:27 GMT</pubDate><enclosure url="https://images.ecency.com/p/4i88GgaV8qiGEw1xifwYz2xp7RJEnNpBZq7dn2K5yopVEuo6KyYGPUgSMp5UQE8FfWtvgNhqS4MAyMbxuFZDBubFWzSKGjaJeNxuibTmXRqecwtratR4WyQenA?format=match&amp;mode=fit" length="0" type="false"/></item><item><title><![CDATA[FIRE ALARM SYSTEMS 5-STANDARDS DEFINITIONS]]></title><description><![CDATA[DEFINITIONS Approved: means acceptable to the authority having jurisdiction Authority Having Jurisdiction: is the organization, office or individual responsible for approving. Labeled: equipment or materials]]></description><link>http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-5-standards-definitions</link><guid isPermaLink="true">http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-5-standards-definitions</guid><category><![CDATA[safety]]></category><dc:creator><![CDATA[angelparrales]]></dc:creator><pubDate>Mon, 16 Apr 2018 15:40:30 GMT</pubDate><enclosure url="https://images.ecency.com/p/PB8ro82ZpZP5xqHVTtgzxr9jRnPYTxeDK7ZMexdNmmDeE1suy2UeMYa1jkmj4Hf6wRqTanMCxVrvyMrkicDs5KWidPqSFvRE4QLf3rQNbjqpo8DL?format=match&amp;mode=fit" length="0" type="false"/></item><item><title><![CDATA[FIRE ALARM SYSTEMS 4-DOCUMENTATION]]></title><description><![CDATA[IMPORTANCE These documents are the construction contract, which governs the rights, duties and liabilities of the contractor who performs the work, the organization for whom the work is executed and the]]></description><link>http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-4-documentation</link><guid isPermaLink="true">http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-4-documentation</guid><category><![CDATA[safety]]></category><dc:creator><![CDATA[angelparrales]]></dc:creator><pubDate>Mon, 09 Apr 2018 23:23:18 GMT</pubDate><enclosure url="https://images.ecency.com/p/54TLbcUcnRm4iYtFdzVNy1kt3F2tvRShXkTnWxjMsrZgCe6FZ6fk7siez1knShq4yGwLcfNfxaLVKVe8a8C67XEvR3VyHPbQTrzBhCdrcnsdc6moR9fz225eADJd4BQLiDnJG72ea?format=match&amp;mode=fit" length="0" type="false"/></item><item><title><![CDATA[FIRE ALARM SYSTEMS 3A-PERFORMANCE BASED DESIGN]]></title><description><![CDATA[This method proposes an approach to design a system such as can detect a growing fire before it reaches certain heat release level, is not applicable to smoldering fires. It is based on modify the listed]]></description><link>http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-3a-performance-based-design</link><guid isPermaLink="true">http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-3a-performance-based-design</guid><category><![CDATA[safety]]></category><dc:creator><![CDATA[angelparrales]]></dc:creator><pubDate>Mon, 02 Apr 2018 12:29:18 GMT</pubDate><enclosure url="https://images.ecency.com/p/2FFvzA2zeqoVZ5NRzV2o8MyJEzowAL6rjbt8w3dTH8cqMW316Ha71zq8SALznmK33p1qpZH2WwMFSZUcXH91kosKdxGonyfGXrkaHN86wdYFPhf3koSYnYHP3sHkz?format=match&amp;mode=fit" length="0" type="false"/></item><item><title><![CDATA[FIRE ALARM SYSTEMS 3-DESIGN]]></title><description><![CDATA[Engineering design is a well structured method to plan and perform every activity to get an proper and effective fire alarm system. This is paramount when it comes to protect life, assets and environment]]></description><link>http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-3-design</link><guid isPermaLink="true">http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-3-design</guid><category><![CDATA[safety]]></category><dc:creator><![CDATA[angelparrales]]></dc:creator><pubDate>Mon, 26 Mar 2018 13:18:33 GMT</pubDate><enclosure url="https://images.ecency.com/p/3W72119s5BjWPGGUiZ9pqnZoj8JHYxCCp9dtn2QVeCHVzFnfTpjEPGXKJjXFhquphdSXHJK4xA9tP4T7kewA8uWiFKgoD54Q5DkEbY36xDmdaoJmdb74bx?format=match&amp;mode=fit" length="0" type="false"/></item><item><title><![CDATA[FLAME DETECTORS - A Summary]]></title><description><![CDATA[Methods for detection of flame rely on optical recognition of fire signatures, this is the phenomena introduced to the surroundings by a fire. NFPA 72 categorizes as Radiant Energy–Sensing Fire Detectors]]></description><link>http://direct.ecency.com/safety/@angelparrales/flame-detectors-a-summary</link><guid isPermaLink="true">http://direct.ecency.com/safety/@angelparrales/flame-detectors-a-summary</guid><category><![CDATA[safety]]></category><dc:creator><![CDATA[angelparrales]]></dc:creator><pubDate>Sat, 24 Mar 2018 23:51:12 GMT</pubDate><enclosure url="https://images.ecency.com/p/cyxkEVqiiLyAJMrzqHfWLT7YbdgoprDQGwdeDRwrGM6q5cBp1HuWYvHbJqSTKkHurmnNiCtBJqTsRVVTjcZn4w3CNJqgEXGR8MG8xeXXKosMTgWp4n3EygZrkK9mT9HkgpE?format=match&amp;mode=fit" length="0" type="false"/></item><item><title><![CDATA[FIRE ALARM SYSTEMS 2-LIMITATIONS]]></title><description><![CDATA[There is no one-size-fits-all in fire alarm system. If a building owner expects that installing only what the building code requires, will detect any fire at every remote part of the building, that simply]]></description><link>http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-2-limitations</link><guid isPermaLink="true">http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-2-limitations</guid><category><![CDATA[safety]]></category><dc:creator><![CDATA[angelparrales]]></dc:creator><pubDate>Mon, 19 Mar 2018 17:11:09 GMT</pubDate><enclosure url="https://images.ecency.com/p/3jpR3paJ37V8t3d5gG8YxUrFtTrvhgCDjjN8jFs787zDYUcscJzEXsvWd7vSRzfaLh1nf2SqL57c2vuKMUfxKdtAJuRjYfeft829YfcZiBmuhhwwKx53bLFveMLncYSrAjVkz?format=match&amp;mode=fit" length="0" type="false"/></item><item><title><![CDATA[FIRE ALARM SYSTEMS 1-OVERVIEW]]></title><description><![CDATA[Fire Alarm System is a feature of a building for protection against the damages of fire. Is a key element in any overall risk management strategy. It can help limit losses in buildings and facilities by]]></description><link>http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-1-overview</link><guid isPermaLink="true">http://direct.ecency.com/safety/@angelparrales/fire-alarm-systems-1-overview</guid><category><![CDATA[safety]]></category><dc:creator><![CDATA[angelparrales]]></dc:creator><pubDate>Sun, 11 Mar 2018 21:00:33 GMT</pubDate><enclosure url="https://images.ecency.com/p/ChYr1cJZCH5MCAy3RJLzdaUfAradUD6Ky3UVSyaC42WDWpeBJQutETuknb4U7jV7Bxj7ZAcFBKgb8Wd8eKVcGGUjABEcpFwhcLFqHFyMXk7JGAuMMrbA8QP48fcaHKVRJ3A625DouRXfc5ydfExhw5DMWtuxV7QxYkszbAXHEqPQRvPLZPcfxARNnkaFvv?format=match&amp;mode=fit" length="0" type="false"/></item><item><title><![CDATA[Bomba con motor diesel vs Bomba con motor electrico ¿Cuál es la mejor opcion?]]></title><description><![CDATA[La NFPA no establece una prerrogativa respecto al tipo de impulsor (diésel o eléctrico) de la bomba principal contra incendios. Hay muchos factores por los cuales se puede elegir una y otra, pero la principal]]></description><link>http://direct.ecency.com/spanish/@joseprada/bomba-con-motor-diesel-vs-bomba-con-motor-electrico-cual-es-la-mejor-opcion</link><guid isPermaLink="true">http://direct.ecency.com/spanish/@joseprada/bomba-con-motor-diesel-vs-bomba-con-motor-electrico-cual-es-la-mejor-opcion</guid><category><![CDATA[spanish]]></category><dc:creator><![CDATA[joseprada]]></dc:creator><pubDate>Fri, 02 Feb 2018 11:35:42 GMT</pubDate></item><item><title><![CDATA[¿Se pueden instalar varias bombas de incendios para suplir la demanda del sistema?]]></title><description><![CDATA[Sí, pero no es recomendable. El manual de la NFPA 20 establece en su aparte 4.9.1. 4.9.1 A centrifugal fire pump for fire protection shall be selected so that the greatest single demand for any fire protection]]></description><link>http://direct.ecency.com/spanish/@joseprada/se-pueden-instalar-varias-bombas-de-incendios-para-suplir-la-demanda-del-sistema</link><guid isPermaLink="true">http://direct.ecency.com/spanish/@joseprada/se-pueden-instalar-varias-bombas-de-incendios-para-suplir-la-demanda-del-sistema</guid><category><![CDATA[spanish]]></category><dc:creator><![CDATA[joseprada]]></dc:creator><pubDate>Fri, 02 Feb 2018 11:25:33 GMT</pubDate></item><item><title><![CDATA[¿Por qué utilizar sistemas de rociadores para proteger una edificación?]]></title><description><![CDATA[Cuando se inventaron los primeros rociadores, la idea primordial de sus creadores era disponer de un sistema de extinción de incendios que cumpliera con dos grandes objetivos: ser confiable y automático.]]></description><link>http://direct.ecency.com/rociadores/@joseprada/por-que-utilizar-sistemas-de-rociadores-para-proteger-una-edificacion</link><guid isPermaLink="true">http://direct.ecency.com/rociadores/@joseprada/por-que-utilizar-sistemas-de-rociadores-para-proteger-una-edificacion</guid><category><![CDATA[rociadores]]></category><dc:creator><![CDATA[joseprada]]></dc:creator><pubDate>Sun, 28 Jan 2018 21:28:30 GMT</pubDate></item><item><title><![CDATA[El mantenimiento de los sistemas contra incendios y la falsa sensación de seguridad]]></title><description><![CDATA[Estadísticamente, casi el 50% de los sistemas contra incendios que fallan, y por ende no funcionan en caso de una emergencia, es por culpa del bajo o nulo mantenimiento. Una de las razones por las cuales]]></description><link>http://direct.ecency.com/nfpa/@joseprada/el-mantenimiento-de-los-sistemas-contra-incendios-y-la-falsa-sensacion-de-seguridad</link><guid isPermaLink="true">http://direct.ecency.com/nfpa/@joseprada/el-mantenimiento-de-los-sistemas-contra-incendios-y-la-falsa-sensacion-de-seguridad</guid><category><![CDATA[nfpa]]></category><dc:creator><![CDATA[joseprada]]></dc:creator><pubDate>Sun, 28 Jan 2018 21:22:27 GMT</pubDate></item><item><title><![CDATA[Listado, Aprobado, Listado UL, Aprobado FM, Listado y Aprobado]]></title><description><![CDATA[Existe una confusión dialéctica respecto a los términos “listado” y “aprobado” en el español, asi como también existe una asimilación de marca asociada a “UL” que se considera indistintamente como listado]]></description><link>http://direct.ecency.com/listado/@joseprada/listado-aprobado-listado-ul-aprobado-fm-listado-y-aprobado</link><guid isPermaLink="true">http://direct.ecency.com/listado/@joseprada/listado-aprobado-listado-ul-aprobado-fm-listado-y-aprobado</guid><category><![CDATA[listado]]></category><dc:creator><![CDATA[joseprada]]></dc:creator><pubDate>Sun, 28 Jan 2018 21:11:09 GMT</pubDate></item></channel></rss>